
Stainless Steel - 160L
Stainless Steel - 160L
THE RECLAIM ENERGY HEAT PUMP, DESIGNED,
MANUFACTURED AND SUPPLIED BY AUSTRALIA’S
LEADING, AND ONLY, DEDICATED RENEWABLE
ENERGY HOT WATER SUPPLIER – SERVICING
AUSTRALIA FOR OVER 15 YEARS.
Not sure? Please ask our friendly team on 0475 666 999
Couldn't load pickup availability
Description
Description
THE RECLAIM ENERGY HEAT PUMP, DESIGNED,
MANUFACTURED AND SUPPLIED BY AUSTRALIA’S
LEADING, AND ONLY, DEDICATED RENEWABLE
ENERGY HOT WATER SUPPLIER – SERVICING
AUSTRALIA FOR OVER 15 YEARS.
How to Request Site Specific Quote?
How to Request Site Specific Quote?
- Choose your Installation Type from the dropdown.
- Click on Get a Quote
- Fill in your details and Upload photos of your existing Unit
- One of our specialists will then review your request to formalize your quote.
Technical Specification
Technical Specification
System Model ID | REHP-CO2-160GL | REHP-CO2-250GL | REHP-CO2-315GL | REHP-CO2-400GL |
---|---|---|---|---|
Tank ID | RE160AGLH | RE250AGLH | AP315AGLH* & RE315AGLH | RE400AGLH |
PTRV Rating (kPa) | 850 | 850 | 850 | 850 |
Type | Glass Lined (GL) | GL | GL | GL |
Total Physical Volume (L) | 163 | 259 | 323 | 420 |
Diameter (A) (mm) | 528 | 613 | 617 | 701 |
Height (B) (mm) | 1317 | 1439 | 1765 | 1699 |
Hot Water Outlet (D) (mm) | 1099 | 1212 | 1531 | 1447 |
PTRV Port (H)/Heat Pump Return (C) (mm) | 1099 | 1212 | 1531 | 1447 |
Sensor (G) (mm) | 439 | 458 | 560 | 556 |
Cold Water Inlet/HP Flow (E/F) (mm) | 189 | 196 | 197 | 221 |
How are the prices calculated?
How are the prices calculated?
- Prices calculated are based on the installation type you select above.
- All prices are after the government rebates & incentives including the Solar Victoria Rebate
- Prices are for like-to-like swap
- An additional charge will be applied for unit relocation and a non-standard switchboard.
- Advertised prices only apply in Melbourne Metro, Greater Geelong & Mornington Peninsula.
Warranty
Warranty
15 Years Tank | 15 Years |
10 Years Compressor | 10 Years |
10 Years Controller | 10 Years |
10 Years Parts & Labour | 10 Years |



We Are Proud To Launch
Our new Reclaim Energy & Panasonic Heat Pump! First partnership of its kind in Australia brings together Panasonic’s revolutionary compressor technology & Reclaim Energy’s innovative hot water system design!





























































Offers the ultimate in quality trusted brands in the market!Smart technology ensures energy savings!
Relax With Our Smart Flexible Features
- SMART CONTROL – 6 Operational Modes allow you to take control over your energy costs and consumption
- ONE-SHOT BOOST – For worry free hot water
- ULTIMATE FLEXIBILITY – Multiple Timer and Temperature Control ensures complete flexibility
- SMART TECHNOLOGY – Smart independent controller design
- REMOTE CONTROL – seamless integration with your PV/Home Management System
- 1300 SUPPORT – Managed 7 days a week, 365 days a year
- 7-YEAR HEAT PUMP & CONTROLLER WARRANTY guaranteed

WHY RECLAIM & PANASONIC?
Energy Savings
With Reclaim Energy's heat pump hot water system you can save up to 80% off your hot water bill. Why? Because the system uses less energy and has a higher thermal output than electric or gas water heaters.
Innovative Technology
Reclaim Energy's new era of hot water heat pumps with industry-leading technology are a superior hot water system from an environmental and energy consumption perspective.
Experience & Quality
Panasonic have sold over 2 million units in the Japanese market since entering the Heat Pump Market over 20 years ago, so you can rely on a quality product designed with experience build up over 20 years.
Reliability
Panasonic Air Conditioners and Heat Pumps are the leading brand in Japan and are manufactured to ensure years of reliable comfort. With a 7 year warranty, you can rest easy with Reclaim & Panasonic.
Features & Benefits
-
Energy Efficient
Enjoy massive long-term energy savings. With Reclaim Energy Heat Pump Hot Water you can save up to 80% off your hot water bill. Why? Because the system uses less energy and has a higher thermal output than electric or gas water heaters. The top-down Heat Pump return heating design ensures quick water recovery. The system is whisper quiet and up to 200% more environmentally friendly than systems that use standard refrigerants.
-
System Model
It is notable that the V2 system model numbers are different from the previously supplied system model numbers. The following codes must be used for rebate applications such as STC, ESC, and VEECs. In terms of STC changes between V1 and V2 models, there has been slight improvement of about 1-3 STCs for different model IDs depending on the system model number and zone.
-
System Model
It is notable that the V2 system model numbers are different from the previously supplied system model numbers. The following codes must be used for rebate applications such as STC, ESC, and VEECs. In terms of STC changes between V1 and V2 models, there has been slight improvement of about 1-3 STCs for different model IDs depending on the system model number and zone.
-
Boost Mode
The Boost mode can also be turned on and off via a momentary press of the boost button. When activated, temperature control mode is enabled, as above, allowing the heat pump to turn on. The heat pump will remain on until the temperature reaches 59˚C (plus 3 seconds), or the 6-hour period has elapsed, whichever occurs first. The On Call LED will start flashing, indicating the heat pump has been turned on via Boost Mode. If inadvertently pressed, boost mode can be turned off by pressing the Boost button again.
-
Time Control Mode
The temperature control mode can be enabled and disabled during certain periods within the 24 hour cycle, as outlined in the options page. The user can select to permanently enable, four preset time periods or can opt for two adjustable time periods (e.g. time zone 1 minimum hours is 3 hours and time zone 2 minimum hours is 0 hours. Also note regardless of what is set for the fi rst time zone, the system for the fi rst cycle only runs until it reaches the set point temperature of 59°C). For the second and subsequent time settings, the time control takes priority over the temperature mode (i.e. the heat pump operation may stop due to time settings before the Toff temperature of 59°C is reached.) When the Time Control Mode is active the Power ON LED fl ashes.
-
Temperature Control Mode
The “temperature control” turns the heat pump on at the T-on setting (37°C), and off at the T-off setting (59°C). On the first start, the heat pump is turned on if the temperature is less than 59°C. On the subsequent starts the heat pump is turned on when the temperature in the tank drops to the T-on setting (37°C) and turns off when the temperature reaches the T-off setting (59°C) which signifies modern HVAC innovation that maximizes efficiency while minimizing space requirements.